GENERAL CONTRACTOR SPECIFICATIONS
Framing of walls and ceiling shall be of dry Doug Fir, construction grade no. 1 or 2, 16" o/c. use pressure treated plates against concrete.
Ceiling shall be 7'-0" from finished floor to ceiling joists (16" o/c)
Door shall be roughed in at 26" x 82" and must open out
Insulation of walls and ceiling shall be of min. R-11 (pref. foil faced) fiberglass batts
Drywall shall be 5/8" Type-X (Only if req'd by local building code - Req's also additional furring strips over drywall)
Added Vapor Barrier shall be Type-C construction foil over insulation or drywall -- walls and ceiling
Flooring shall be of hard surfaced, waterproof type -- concrete, ceramic tile, heavy duty seamless vinyl
Floor drain is recommended for new construction and is essential for commercial and public Saunas
Exterior walls shall be of drywall, paneling, etc. and exterior painting, door finishing, etc. shall be included
ELECTRICAL CONTRACTOR SPECIFICATIONS
(Must be licensed and bonded)
Rough-in for Sauna controls, heater, room light shall be as per wiring diagram (provided with control box or in heater box / supplied by Springs Sauna Company on case by case bases)
Hookup of controls, heater, and light shall be as per Finlandia wiring diagram. COPPER WIRE ONLY